Fire alarm zone plan software

Fire alarm zone plan software: the zone plan for the panel, drawn once and kept right.

Draw the building's zones over a photo of the old chart or the floor plan, drop each detector, call point and sounder where it is, and print the zone plan for the panel wall. The same plan goes on every certificate and stays up to date visit after visit.

The zone plan editor: rooms, zones, detectors, call points and sounders on a ground floor plan with a title block
A fire alarm zone plan in the editor, with made-up demo data.

What it does

Fire alarm zone plans, in practice

01

Start from the chart on the wall

Take a photo of the existing zone chart or the floor plan and draw over it, or start from a blank page and draw the rooms.

02

Zones drawn, not described

Draw each zone's area on the plan, with a level for each floor, so the zone plan by the panel shows exactly where each zone is.

03

Devices on their loops

Pick a detector, call point or sounder and tap where it goes. It takes the next free address on the loop, and Kerova warns you if two share an address.

04

Passed and failed on the plan

During the service each device turns green or red, so a failed call point is a red dot in the right room on the certificate.

05

Print it for the panel

Print the plan simply for the panel wall, or as a full drawing with a title block, key, revisions and your logo.

06

The client sees it too

The plan is in the client's portal with the certificate, showing any device that failed its last test. They can't change it.

Why the zone plan matters on a fire alarm

When the panel shows a fire in zone 4, whoever is there has to find zone 4 quickly. That's what the zone plan by the panel is for, and BS 5839-1 expects one. It's also the first thing to go out of date when a building changes. In Kerova the zone plan is part of the system's record, so the engineer sees it on every visit and fixes it there and then, and the next certificate prints the plan as it is now.

  • Check your zones with the free fire alarm zone checker (floor area, search distance and floors per zone).
  • Revisions kept on the title block, so you know which plan went out.
  • Repairs linked to devices: a repair knows exactly which detector it's for.
  • As-fitted drawings too: the same plan, printed with the device schedule for handover. See zone plans and as-fitted drawings for every discipline.
A fire alarm certificate on a phone, section 1 of 16, with Mark complete at the bottom
The zone plan goes on the fire alarm certificate the engineer signs on site.

Questions

Common questions

Do I need CAD?

No. It's drawn in the app with your finger or a mouse. If you use CAD, you can export a DXF, and a picture of an existing drawing can be the background you draw over.

Can I update the zone plan on site?

Yes. On a phone the plan fills the screen. Most firms draw it in the office and update it on site when something has changed.

Does it go on the certificate?

Yes. The fire alarm certificate prints the zone plan with each device's result from that visit.

Can the same plan hold other systems?

Yes. Symbols are grouped by system, so one plan can hold the fire alarm, emergency lighting and more, or you can keep a plan per system.

Ready when you are

Draw your first zone plan this week, free for a month.

Start a free trial and we set your company up, or get in touch with a question.

First month free · no card · we help you set up