Guides
Practical reading for people who sign certificates.
Short, specific guides on the standards fire & security engineers work to and the admin around them. No fluff, no clause-number bluffing.
PAT retest intervals: how often to test each appliance
What decides each appliance's retest interval, the checks in between, and how to keep track of it.
Fire alarmBS 5839-1 testing intervals: weekly, monthly, six-monthly and annual
The weekly call point test, the monthly checks, six-monthly servicing and the annual test of every device: who does what, and what is recorded.
Fire alarmWhat goes on a BS 5839-1 service certificate
The system, what was tested, the battery sum, false alarms, defects and signatures: what the record needs.
Emergency lightingEmergency lighting test frequencies explained: monthly, annual and five-yearly
The function test, the 1 or 3 hour full-duration test, the five-yearly light check, and what the record must show.
CertificationWhat makes a fire or security certificate compliant?
The parts that get certificates rejected by auditors and insurers — and the ones people forget.
Fire extinguishersHow often should a fire extinguisher be serviced?
The monthly look-over, the yearly basic service, the 5 year extended service and the CO2 overhaul.
Fire extinguishersHow many fire extinguishers does a building need?
Ratings for each storey, how far anyone should walk, mounting heights and choosing the type.
Fire alarmHow many smoke detectors does a room need?
How far a detector reaches, the grid, walls and corridors, with a worked example.
Fire alarmHow far apart can manual call points be, and how high do they go?
The 45 m and 30 m distances, the 1.4 m height and what changed in 2025.
Fire alarmBS 5839-1:2025: what's changed for installers
The 2025 changes that affect what you fit, sign and write down, in plain words.
Fire alarmFire alarm categories: L1 to L5, M, P1 and P2 explained
What each category means, and what changed for bedrooms and stairway lobbies.
Fire alarmHow to work out a fire alarm battery size
The Annex E formula step by step, the standby times, a worked example, and fitting and checking.
Emergency lightingHow much light does emergency lighting need?
Lux levels for escape routes, open areas and fire equipment, and how long the light must last.
Intruder alarmIntruder alarm grades 1 to 4: which one do you need?
What the grades and environmental classes mean, PD 6662, notification options and police response.
CCTVCCTV pixel density: how many pixels do you need to identify someone?
How it is worked out, the 2025 levels, and why it is only part of the picture.
Access controlFail-safe or fail-secure locks: what is the difference?
Which suits an escape route, and how BS 7273-4 categories A, B and C work.
CertificationWhich certificate does each fire alarm or emergency lighting job need?
Design, installation, commissioning, acceptance, servicing and modification, and who signs each.
Running the businessCharging late payment fees on overdue invoices (UK)
The £40, £70 or £100 fixed sum and 8% over base rate interest for business clients, with a worked example.
Running the businessPaper certificates vs digital: what actually changes
An honest comparison for a small fire & security company: cost, time on site, disputes, and what clients notice.
Put it into practice
The registers and readings in these guides are built into Kerova's certificates.
Try them on your own sites, free for a month.
First month free · no card · we help you set up