AOV inspection certificate software · BS EN 12101
AOV inspection certificate software: smoke vents tested vent by vent.
Each vent opens on a fire signal, closes on reset and opens in time: test it, tap the result, move on. Manual controls, weather sensors, the panel battery and the fire alarm link go on the same certificate.
Certificate types: Periodic Inspection & Servicing · Commissioning · Takeover · Alteration / Modification

On the certificate
What the aovs and smoke vents certificate records
The system on record
Control panel make, model and location, power supply and standby battery, whether it is linked to the fire alarm, where the manual controls are, and any rain or wind sensors.
A vent register
Each vent's ref, location, type (window, roof, louvre, shaft, natural or mechanical), actuator and free area, carried forward to the next visit.
Vent-by-vent tests
Opens fully on a fire signal, closes on reset, and the opening time in seconds, against last time's figure.
The service checklist
Opens and closes from each manual control, actuators, chains and fixings, rain and wind sensors, panel battery and charger, the fire alarm interface and reset.
Batteries tracked
The panel's battery date is recorded, so Kerova reminds you when it is coming up for replacement.
Failed vents become repairs
A vent that doesn't open on a fire signal or close on reset becomes a repair, and goes on the draft quote for the client to approve in their portal.
On site
A aovs and smoke vents visit on your phone, start to finish
- Open the site. The panel, its battery and every vent are there from the last visit.
- Fire signal. Open the vents on a fire signal and record each one's opening time against last time's.
- Reset and manual controls. Close on reset, then open and close from each manual control.
- Sensors and battery. Rain and wind sensors, the panel battery and charger, and the fire alarm link.
- Sign and send. The client signs, and a vent that didn't open or close is a repair on a draft quote.
No signal? Everything saves on the phone and sends when you're back in range. Once it's signed, anyone can scan the QR code on the certificate to check it's genuine, and the client finds it in their portal with what's due next.
Which standards it is tested against
The certificate names the BS EN 12101 series (the parts for natural vents, control panels and power supplies), BS 9999, Approved Document B and BS 7346-8 where it applies, without quoting them. It gives one of three plain results: Satisfactory, Satisfactory with advisories, or Unsatisfactory – repairs needed. Services are due every 12 months by default; the engineer can change the next due date on the certificate if your contract says otherwise.
The same on every discipline
One app for the certificate, the client and the invoice.
- ✓ Locked when signed, changes make a new revision, and anyone can check it by its QR code without logging in
- ✓ A client portal with what's due, signing on screen and fault reporting
- ✓ Failed items become repairs, then a quote and an invoice, sent to Xero
- ✓ Devices on a zone plan or as-fitted drawing that prints with the certificate
- ✓ Works with no signal in a plant room or basement: it saves on the phone and sends when you're back in range
- ✓ Service reminders go out for you, to you and the client
Related guides
What makes a fire or security certificate compliant?
GuidePaper certificates vs digital: what actually changes
Free tools that help
DC voltage drop calculator
Free calculatorOhm's law and power calculator
Free converterElectrical unit converter
Questions
AOVs and Smoke Vents in Kerova
Does it work for mechanical systems too?
Vents can be recorded as natural or mechanical, and the checklist and vent tests cover both. Complex smoke control systems may need your own commissioning paperwork as well.
Can the AOV certificate sit with the fire alarm one?
Yes. Both systems at a site go in one compliance pack and one portal view for the client, and the fire alarm interface check is on the AOV certificate.
Other disciplines
Fire Alarm
See the certificate →PD 6662 / BS EN 50131Intruder Alarm
See the certificate →BS 5266-1Emergency Lighting
See the certificate →BS 5306-3Fire Extinguishers
See the certificate →BS EN 62676-4CCTV
See the certificate →BS EN 60839-11-1Access Control
See the certificate →BS 8214Fire Doors
See the inspection report →IET Code of PracticePAT Testing
See the record →Every discipline is part of the same fire and security software: one account, one price for the firm.
Ready when you are
Aovs and smoke vents certificates on your own sites, free for a month.
Start a free trial and we set your company up, or get in touch with a question.
First month free · no card · we help you set up