- Addressable
- A fire alarm system where every device has its own address, so the panel shows exactly which device has operated.
- Ah (amp hour)
- A measure of battery capacity. A battery that can supply 1 amp for 7 hours is 7 Ah.
- Anti-panic area
- A large open area where people need enough light to see where they are going and find the way to the exits if the lights fail.
- ARC (alarm receiving centre)
- A monitoring centre that receives alarm signals from premises and acts on them.
- ATS (alarm transmission system)
- The link that carries alarm signals from a building to the monitoring centre, such as a phone line, mobile signal or internet connection.
- Basic service
- The yearly service of a fire extinguisher by a competent person.
- Beam detector
- A detector that sends a beam of light across a room and raises the alarm when smoke blocks or weakens it. It suits large, high spaces.
- BS (British Standard)
- A standard published by BSI, the British Standards Institution.
- Central battery
- An emergency lighting system where one battery system feeds many light fittings, instead of a battery in each one.
- CIE (control and indicating equipment)
- The fire alarm control panel.
- Class A
- A fire in ordinary solid materials such as wood, paper and cloth.
- Class B
- A fire in flammable liquids such as petrol and paint.
- Class C
- A fire in flammable gases.
- Class D
- A fire in metals.
- Class F
- A fire in cooking oils and fats.
- Commissioning
- Setting up and testing a new system at handover, to show that it works as designed.
- Competent person
- Someone with the training, skill and experience to do a job safely and correctly.
- Condemned
- Taken out of use because it is no longer safe or fit for its job. A condemned extinguisher is withdrawn and not put back into service.
- Controller
- The unit in an access control system that decides whether to open a door, using what the reader tells it.
- Conventional
- A fire alarm system where devices are wired in zones. The panel shows which zone has operated, not which device.
- Credential
- What a person uses to prove who they are to an access control system, such as a card, fob, PIN or phone.
- DORI
- Detect, Observe, Recognise, Identify: the four main CCTV levels in the 2015 edition of EN 62676-4. The 2025 edition replaced them with seven levels.
- EN (European Norm)
- A standard agreed across Europe. Many British Standards are the European standard with a British cover, such as BS EN 1838.
- End-of-line device
- A component fitted at the end of a circuit so the panel can monitor the circuit for faults.
- Escape route
- The way people take to get out of a building in an emergency.
- Extended service
- A fuller service of a fire extinguisher, done every five years for most types, where the extinguisher is stripped down, checked and refilled.
- Fail-safe
- A lock that releases when the power is removed.
- Fail-secure
- A lock that stays locked when the power is removed.
- False alarm
- An alarm with no real fire, break-in or other emergency behind it.
- Field of view
- How wide an area a camera can see, given as an angle.
- Grade (intruder alarm)
- A number from 1 to 4 for the level of risk an intruder alarm is designed to resist. A higher number means a more capable intruder.
- Hydraulic test
- A pressure test using water, to check that an extinguisher body is strong enough for continued use.
- IEC (International Electrotechnical Commission)
- The body that writes international standards for electrical and electronic equipment.
- Isolator
- A device on a fire alarm loop that cuts off a short-circuited section so the rest of the loop keeps working.
- Log book
- The record kept with a system of tests, events, faults, false alarms and services.
- Loop
- A cable that runs from the fire alarm panel through the devices and back to the panel, so it can be fed from both ends.
- Luminaire
- A light fitting. An emergency luminaire has its own battery or is fed by a central battery.
- Lux
- A measure of how much light falls on a surface.
- Maglock
- A lock that holds a door shut with an electromagnet. It releases when the power is removed.
- Maintained
- An emergency light that is on all the time and stays on when the mains fails.
- MCP (manual call point)
- The break glass unit someone operates to raise the fire alarm.
- Multi-sensor
- A detector that reads more than one thing, such as smoke and heat, and combines them to decide on an alarm.
- Non-maintained
- An emergency light that is off until the mains fails, then comes on.
- NVR (network video recorder)
- A recorder that stores video from network cameras.
- Operational requirement
- A written statement of what each CCTV camera is for, such as spotting movement or identifying a face. The design is checked against it.
- PD (published document)
- Guidance from BSI that is not a full British Standard. PD 6662 is the UK scheme for applying the intruder alarm standards.
- Photometric check
- A measurement of light levels, to confirm an installation still meets its design.
- PIR (passive infrared detector)
- A detector that senses the heat of a moving person. It is the usual detector in an intruder alarm.
- PoE (power over Ethernet)
- Power supplied to a device through its network cable.
- ppm (pixels per metre)
- How many pixels of a camera image cover one metre of the scene. It measures how much detail a camera captures at a distance.
- PSU (power supply unit)
- The unit that converts mains power to the low voltage a system needs, and usually charges a standby battery.
- Rated duration
- How long emergency lighting must keep working on its battery. It is 1 hour or 3 hours, depending on the building.
- Reader
- The unit at a door that reads a card, fob, PIN or phone and passes it to the controller.
- Responsible Person
- The person in control of the premises, who has the duty to keep fire safety measures working.
- REX (request to exit)
- A button or sensor on the inside of a door that opens it for someone leaving.
- Self-contained
- An emergency light with its own battery inside the fitting.
- Sounder
- The unit that gives the audible alarm.
- Standby
- The normal ready state of a system, with no alarm or fault. Battery standby is the time the batteries keep the system running if the mains fails.
- Tamper
- A switch or circuit that raises an alarm if someone opens a cover or cuts a cable.
- Uniformity
- How even the light is. It is the brightest reading divided by the dimmest, so a smaller number is more even.
- URN (unique reference number)
- A reference number that a police force issues to a monitored alarm system so that it can get a police response.
- VAD (visual alarm device)
- A flashing light that shows an alarm to people who cannot hear the sounders.
- Variation
- A departure from a recommendation in the standard, which is agreed with the client and recorded.
- VMS (video management software)
- The software that shows, records and manages CCTV cameras.
- Zone
- An area of a building covered by a group of detectors, shown as one area on the fire alarm panel.