Intruder alarm · PD 6662

Intruder alarm grades 1 to 4: which one do you need?

Quick answer

An intruder alarm's grade says what kind of intruder it's designed to resist, from Grade 1 (low risk, little knowledge, easily available tools) to Grade 4 (high risk, where security comes before everything else). Grade 2 is most homes and many small businesses; Grade 3 suits higher-risk premises such as shops with high-value stock.

What the grades mean

A security grade says what kind of intruder the system is designed to resist. The higher the grade, the more capable the intruder it expects:

GradeRiskThe intruder it is designed to resist
1LowLittle knowledge and a limited range of easily available tools
2Low to mediumLimited knowledge and a general range of tools and portable instruments
3Medium to highA comprehensive range of tools and portable electronic equipment
4HighUsed when security takes precedence over all other factors

Where each grade typically turns up:

  • Grade 1: rare in professional installs.
  • Grade 2: most homes and many small businesses.
  • Grade 3: shops with high-value stock, offices with IT, many commercial sites. Often an insurer's requirement.
  • Grade 4: specialist sites only.

The grade is set from the risk to the premises. Insurers and inspectorates often name the grade they need, so check what a policy asks for before you design.

The whole system is only as good as its lowest-graded part. A grade 3 panel with grade 2 detectors is a grade 2 system. Check the grade marking on every component against the system grade on the certificate. The intruder alarm grades explained page sets the grades side by side.

What PD 6662 is

PD 6662 is the UK scheme for applying the European standards, BS EN 50131, to intruder and hold-up alarm systems. Insurers, the police and the inspectorates (NSI and SSAIB) work to it. The 2017 edition is the current one. It was updated in June 2019 to use undated references, and the notification options moved into BS EN 50131-1.

Environmental classes

Separately from the grade, equipment is given an environmental class, which says where it can be fitted, by the temperature range it works over:

  • Class I: indoors with a well maintained temperature, +5 to +40 °C
  • Class II: general indoor areas, −10 to +40 °C, such as an unheated corridor or store
  • Class III: outdoors and sheltered, −25 to +50 °C, such as under a canopy
  • Class IV: outdoors and general, −25 to +60 °C, fully exposed to the weather

A class II detector in an unheated warehouse in January, or a class II sounder on an exposed wall, is a fault waiting to happen.

Detectors and masking

Anti-masking (a detector noticing it has been covered or sprayed) steps up with the grade, and at grade 3 and above it matters to how the system reports. Rather than rely on memory, check the detector's datasheet and grade marking against the system grade you are installing to.

Notification options

How an alarm gets reported (sounders only, or one or two signalling paths to an alarm receiving centre) is set by the notification option. PD 6662:2017 moved these options into BS EN 50131-1 itself, aligned with the transmission categories in BS EN 50136-1, so the lettering differs from the older PD 6662:2010 options. If an old specification or insurer's letter uses the 2010 letters, translate them before you quote. For example, 2017's option 2E is the direct equivalent of 2010's 2X.

Police response

A system with a police unique reference number (URN) gets police response until there are three false calls in a rolling 12 months. A written warning follows after two. Response is withdrawn no sooner than 14 days after the letter, and the URN is deleted if response stays withdrawn for over 6 months.

Police policy is updated from time to time, so check the current version. A false call is an alarm caused by detector activation with no damage or entry, or by a line fault, unless proved otherwise. The installer, maintainer, customer and receiving centre must all filter false calls, following BS 8473.

How often is it maintained?

Trade guides that cite BS 9263 give: one visit a year for a bells-only system, two a year for a monitored system (or one site visit plus one remote check), and two site visits a year for Grade 4. Check the standard for the exact wording.

Standby battery hours

The battery has to keep the system going through a mains failure. The hours depend on the grade. Under EN 50131-6 and PD 6662, grades 1 and 2 need 12 hours, and grades 3 and 4 need 60 hours, or 30 hours where mains failure is signalled to an alarm receiving centre (ARC).

Size the battery from the panel's and devices' standby and alarm currents, allow for de-rating in alarm and for ageing, and pick the next battery size up. Our battery calculator puts these into an estimate; it is not a compliance check. Check the panel maker's own figures too: makers use different ageing allowances, and they state the maximum recharge time their charger is designed for.

Common questions

What is a Grade 2 intruder alarm?

Grade 2 is low to medium risk. It is designed to resist an intruder with limited knowledge and a general range of tools and portable instruments.

Which intruder alarm grade do insurers want?

It depends on the insurer and the risk. Insurers and the inspectorates (NSI and SSAIB) work to PD 6662, so check what the policy asks for.

What is PD 6662?

The UK scheme for applying the European standards, BS EN 50131, to intruder and hold-up alarm systems. The 2017 edition is the current one.

Can I fit grade 2 detectors to a grade 3 system?

Not if it is to stay grade 3. A system is only as good as its lowest-graded part, so a grade 3 panel with grade 2 detectors is a grade 2 system.

When do the police stop responding to an intruder alarm?

A system with a police URN gets response until three false calls in a rolling 12 months. A written warning follows after two, and response is withdrawn no sooner than 14 days after the letter.

This guide is general information for UK fire & security companies, not legal or engineering advice. Always work to the current edition of the relevant standard and your own competent-person judgement.