Dry riser inspection and test record
Quick answer
A dry riser inspection and test record lists the riser's inlet and every landing valve, floor by floor, with the condition of each, the test pressure and how long it was held, any leaks, and the defects and remedial work. Write in the pressure and time your test procedure uses; this sheet doesn't print them.
One record per riser: the inspection of the inlet and every outlet up the building, the test, and what needs putting right.
What it's for, and how often
- Visual inspection: At the intervals BS 9990 and the building's own maintenance plan set: everything there, undamaged, secure and accessible.
- Test: At the intervals set for the test: the riser filled and held at the test pressure for the set time, each outlet and joint checked for leaks.
- Defects: Written down with what was done, and kept with the building's fire safety records.
What's on it
- Riser details: building, riser reference, inlet location, number of landing valves
- Inlet checks: box, door and glass, inlet valves and caps, drain, signs
- Landing valves floor by floor: valve, cap and chain, strap and padlock, box, leaks under test
- Test record: pressure, time held, result
- Defects and remedial work, and sign-off
It's our own layout, made to be filled in by hand on site. It works to BS 9990 but doesn't quote it, so keep a copy of the current edition to hand.
Coming to Kerova, get early accessWe're building riser records into Kerova with the firms that do the work: filled in on the phone, signed on site, with a QR check on every one. It isn't in the app yet. See what's planned.
Get early accessRelated
- Dry and wet riser inspection software (coming to Kerova)
- AOV and smoke vent certificates in Kerova
- Fire door inspection checklist template
More free templates
- Fire alarm weekly test and event logbook (BS 5839-1)
- Emergency lighting monthly and annual test log (BS 5266-1)
- Fire extinguisher service record (BS 5306-3)
- Fire door inspection checklist (BS 8214)
- Intruder alarm service checklist (PD 6662 / BS EN 50131)
- PAT testing log and appliance register (IET Code of Practice)
- Sprinkler weekly test log (BS EN 12845)
- Sprinkler system log book (BS EN 12845)
- Legionella water temperature monitoring and flushing log (HSE L8 and HSG274)
- Gate and barrier safety inspection checklist (BS EN 12453)
- Lightning protection inspection and test record (BS EN 62305)
- Ductwork cleaning record (BESA TR19)
- All templates